DSP Card Status

System/Sub-System

MiVoice Business: Hardware

Description

A DSP card is defective. A Critical alarm results when no DSP cards are installed.

Alarm Status

The minor threshold is 1. The critical threshold is 100.

Possible Cause Corrective Action
DSP Hardware failure or the DSP card is not installed properly.

For a defective DSP module, ensure that the module is seated securely. For an embedded DSP failure, replace the controller.

Use Show Status DSP maintenance command to identify the location of the defective module. Reset the system as soon as possible. If the DSP continues to fail, replace the module.

References